FP104 · unused-input
An input is declared but never read anywhere in the workflow or action.
| Code | Name | Category | Default severity | Reported by |
|---|---|---|---|---|
FP104 | unused-input | Inputs | 🟡 warning | lint, check, the action, the editor |
What you see
In the composite-actions fixture:
▲ WARN FP104 unused-input
Input "token" of .github/actions/install-tools is never read
▶ .github/actions/install-tools/action.yml:10:3Why it matters
Dead inputs accumulate in large interfaces: callers keep computing and passing values that go nowhere, and readers assume a knob works when it does not.
How to fix
Remove the input (and the callers’ bindings), or wire it to where it was meant to be used.
Example
on:
workflow_call:
inputs:
legacy-flag: { type: boolean } # never referencedScope
Not reported in generated files, which are not edited by hand.
Accept one finding
When a finding is intended, accept it with a reason rather than turning the rule off. It is listed apart from the other findings, and does not fail the build.
On its line, with an ignore comment alone on the line above it (the
editor's quick fix adds it there) or at the end of the line, after any other comment such as a version
(# v4.3.0 # flowpact: ignore[FP104] why):
# flowpact: ignore[FP104] why it is acceptable here
token:In the config, with an override, which can expire:
overrides:
- rule: FP104
target: ".github/actions/install-tools#inputs.token"
reason: Why it is acceptable here, at least 10 characters.
expires: YYYY-MM-DD # optionaltarget is the symbol the finding is about; to list them:
flowpact lint --format json | jq -r '.findings[] | select(.code == "FP104") | .symbol'* matches within a path segment and ** across segments, so one entry accepts every finding whose symbol matches:
target: '**#inputs.app-id' is that input in every workflow and action.
Change the severity
Change the severity (or turn the rule off) in .github/flowpact/flowpact.config.yml, by code or by name:
rules:
FP104: off
# or: unused-input: errorExplain it in the terminal:
flowpact explain FP104